Vacuum Sensors

4 products


  • Elitech Wireless Micron Gauge 1~19,000 Microns, Digital Vacuum Gauge for HVAC and automotive, Refrigerant Vacuum Meter 1/4" SAE Shop All Categories BVV

    Wireless Digital Vacuum Gauge 1~19,000 Microns

      VGW-mini Wireless micron vacuum gauge measures vacuum via just one service port and with no loss of refrigerant. Its compact, robust and smart design support HVAC technicians with numerous intelligent features like the graphic display of measurement data in the Elitech Tools App. Its smart Bluetooth integration allows for data to be stored and evaluated reliably and efficiently, thus saving precious time and resources. Product Features High Accuracy The digital vacuum gauge achieves precise deep vacuum measurements down to single digit resolutions and provides notifications when the evacuation target is met. Smart APP Control Control your micron tester remotely and navigate through all measurement data via Smartphone or Tablet. Quickly and conveniently document your job, finalize your report and export - directly from the job site. Intelligent Judgement of H2O Status The vacuum meter automatically judges physical state of H2O by comparing ambient temperature and water saturation temperature corresponding to the vacuum in the system. Large, Easy-to-Read Display Continual digital readout of evacuation process can be viewed easily on the large, full-view LCD screen. Rechargeable Lithium Battery Built-in rechargeable lithium battery can work up to 20 hours per single full charge, saving troubles of frequent battery change.     Product Specifications Measuring Range: 0-19000 micron Operating Temperature: -4℉~140℉ (-20°C~60°C) Interface: 1/4 SAE Accuracy: 1~10,000 microns: ±10% of readings ±10 microns10,000~19,000 microns: ±20% of readings Resolution: 0-400 1 Micron400-3000 10 Micron3000-10000 100 Micron10000-19000 250 Micron Vacuum Units microns, mTorr, in/hg, Pa, Torr, KPa, mbar and psia Battery rechargeable lithium battery (1,000mAh) Overload 27.5 bar Certification CE

    $170.00

  • Digital Vacuum Chamber Gauge Upgrade Unclassified BVV

    Digital Vacuum Chamber Gauge Upgrade *Wireless

    Digital Vacuum Chamber Gauge Upgrade *Wireless After many requests, we have combined our infamous vacuum tight bulkhead with the power of a wireless vacuum gauge that can be a simple upgrade to ANY of our vacuum chamber products or resin traps.  For those seeking truly accurate readings at any altitude and wireless monitoring this is the ultimate gauge for any vacuum system!. *To install: All that is required is a 1/2" wrench to remove the original and replace the digital one.    The VGW-mini Wireless micron vacuum gauge measures vacuum via just one service port and with no loss of refrigerant. Its compact, robust and smart design support HVAC technicians with numerous intelligent features like the graphic display of measurement data in the Elitech Tools App. Its smart Bluetooth integration allows for data to be stored and evaluated reliably and efficiently, thus saving precious time and resources. Product Features High Accuracy The digital vacuum gauge achieves precise deep vacuum measurements down to single digit resolutions and provides notifications when the evacuation target is met. Smart APP Control Control your micron tester remotely and navigate through all measurement data via Smartphone or Tablet. Quickly and conveniently document your job, finalize your report and export - directly from the job site. Intelligent Judgement of H2O Status The vacuum meter automatically judges physical state of H2O by comparing ambient temperature and water saturation temperature corresponding to the vacuum in the system. Large, Easy-to-Read Display Continual digital readout of evacuation process can be viewed easily on the large, full-view LCD screen. Rechargeable Lithium Battery Built-in rechargeable lithium battery can work up to 20 hours per single full charge, saving troubles of frequent battery change.     Product Specifications Measuring Range: 0-19000 micron Operating Temperature: -4℉~140℉ (-20°C~60°C) Interface: 1/4 SAE Accuracy: 1~10,000 microns: ±10% of readings ±10 microns10,000~19,000 microns: ±20% of readings Resolution: 0-400 1 Micron400-3000 10 Micron3000-10000 100 Micron10000-19000 250 Micron Vacuum Units microns, mTorr, in/hg, Pa, Torr, KPa, mbar and psia Battery rechargeable lithium battery (1,000mAh) Overload 27.5 bar Certification CE

    $178.00

  • KF-25 x KF-25 x 1/8" FNPT Adapter Shop All Categories BVV

    KF-25 x KF-25 x 1/8" FNPT Adapter

    KF-25 x KF-25 x 1/8" FNPT Adapter This 304 stainless steel KF-25 adapter is specifically designed for adapting Digivac Bullseye Precision Vacuum Gauges to systems with reducing and minimizing connect / leak points on the system.

    $27.00

  • FYRA End of Primary Drying Detection Kit Unclassified BVV

    FYRA for End of Primary Drying Detection | Vacuum Drying Monitoring | for Lyophilization| CE, UL, CSA

    FYRA for End of Primary Drying Detection.  This bundle is set up to allow for vacuum drying applications like freeze-drying and vacuum ovens to help determine the end of drying. Will help you detect when most of the water or residual solvent from a product has been removed or the end of primary drying has been reached in a vacuum drying application. Background on How this FYRA End of Primary Drying package works: When a freeze dryer is equipped with both a thermal and direct measurement, these sensors can be utilized to indicate the end of primary drying (Source). Step One: Clean process documentation | Get a baseline Characterize the convection-enhanced Pirani and the capacitance manometer (in this case the DCP Quantum) against each other in a dry, empty and refrigerated system. The freeze dryer is turned on, as per the manufacturer’s operator manual, with nothing on the shelf. The shelf temperature can be left at room temperature, and if so the cold trap, the condenser, and the vacuum pump should be on and running for a period of time The vacuum oven or freeze dryer is allowed a period of time to become stable in this condition and the Pirani and capacitance manometers are read. The difference in their pressure readings in a dry, empty and refrigerated freeze dryer will be relatively small (mT to 10’s of mT) when the system is working properly. DigiVac will NOT calibrate these two gauges against each other. There may always be slight differences in their readings due to their difference in design. The difference in pressure (ΔP) between these two gauges, when dry, empty, and refrigerated, indicates how close they come together when there is little to no water vapor in the gas mix over the product. Step 2: Drying with Product The intent of primary drying is to maximize the sublimation rate within the product. As such the gases in the chamber have a high water vapor content. The Pirani sensor will read a higher pressure than the capacitance manometer. As freeze drying progresses the amount of ice converting to vapor through the sublimation process will decrease as the product becomes lyophilized from the top through the bottom of the product. Eventually, the Pirani and capacitance manometers will approach the ΔP that was established in a dry, empty and refrigerated system. Approaching this ΔP value indicates that the end of primary drying has occurred. The DigiVac FYRA controller has a rich remote command-line interface which enables the user a high degree of remote control and monitoring from any computer when communicating through the USB port. Calibrated—Every FYRA is calibrated and pretested under actual vacuum against a NIST standard (Need NIST traceable documentation? Add this option to your order) Applications—Ideal for End of Drying Detection, Freeze Drying Primary Drying Monitoring, and Vacuum Oven Drying Monitoring and Detection DCP Quantum DuoSense Measurement Range: .05 mT to 1000 Torr 275 Convection-enhanced Pirani Measurement Range: 0.1mT to 1000 Torr FYRA Bleed Vacuum Controller Components: FYRA controller Convection-enhance Pirani KF25  gauge sensor | Lesker 275, driver card, and Pirani sensor cable Quantum DCP Gauge and driver card | DuoSENS Capacitive Piezo Vacuum Sensor 0.01 to 1000 Torr, Gas Independent 3 Simple Steps for Vacuum Process Set-up with FYRA Vacuum Controller: Plumb the vacuum gauge(s) and valve into your vessel Connect the sensor, power, and I/O cables into FRYA Measure and control vacuum

    $3,456.00

Login

Forgot your password?

Don't have an account yet?
Create account